☎ +91 99926 66137✉ info@kcscientificworks.com
Scientific Instruments for Better TomorrowQuality DocumentsCompany ProfileDealer / Enquiry
Scientific Instruments for Better TomorrowEnquire Now
← Back to Microscope
MULTI HEAD MICROSCOPE KCX-179
Microscope / Multiview Microscopes

MULTI HEAD MICROSCOPE KCX-179

The Multi Head Microscope KCX-179 by KC SCIENTIFIC WORKS is a collaborative laboratory microscope featuring infinity-corrected DIN Plan Achromatic objectives, a multi-observer viewing system, precision mechanical stage, green LED pointer and Köhler illumination. Designed for teaching, research demonstrations and laboratory training, it enables shared observation of suitable biological specimens.

SKU: KCX-179

Category: Microscope, Multiview Microscopes

Description

Contact our team for a detailed product description.

Technical Specifications

ParameterSpecification
Product NameMulti Head Microscope
Model NumberKCX-179
BrandKC SCIENTIFIC WORKS
ManufacturerKC SCIENTIFIC WORKS
Microscope TypeMultihead Biological Compound Microscope
Observation SystemMulti-Observer Optical Viewing
Optical SystemIP Series Infinity-Corrected
Objective StandardDIN Plan Achromatic
Objective TreatmentAntifungal
NosepieceQuintuple Reverse-Angle Revolving Nosepiece
Nosepiece MechanismBall Bearing
Objective 14X, N.A. 0.10
Objective 210X, N.A. 0.25
Objective 340X, N.A. 0.65, Spring-Loaded
Objective 4100X, N.A. 1.25, Spring-Loaded, Oil Immersion
Calculated Magnification40X, 100X, 400X and 1000X with 10X Eyepieces
Eyepiece MagnificationNot Specified in Reference
Number of Viewing HeadsNot Specified in Reference
Multihead ObservationShared Specimen Viewing
PointerGreen LED
Pointer BrightnessAdjustable
Stage TypeDouble-Layer Graduated Rectangular Mechanical Stage
Stage Size185 × 142 mm
Stage Cross Travel75 × 55 mm
Stage ControlsBall-Bearing Coaxial
CondenserSwing Condenser
Condenser N.A.0.9 / 0.25
Condenser LensAspheric
DiaphragmIris Diaphragm
Optical FilterSpecial Daylight Blue Filter
Focusing MechanismLow-Positioned Coaxial Coarse and Fine
Focusing FeaturesTension Control and Refocusing Lock
Illumination SystemKöhler Illumination
Illumination ArrangementExternal
Light SourceHalogen
Lamp Rating12V / 50W
Main ApplicationsMicroscopy Teaching, Laboratory Training and Collaborative Observation
Product CategoryMultihead Teaching and Research Microscopes

Key Features

  • 1. Advanced Multi Head Microscope
  • The KCX-179 Multi Head Microscope is designed for collaborative microscopy, scientific demonstrations, laboratory training and educational observation.
  • Its multi-observer configuration allows several users to examine the same specimen during a microscopy session.
  • 2. Multi-Observer Optical Design
  • The microscope uses a shared optical observation arrangement intended for simultaneous specimen viewing.
  • This makes the KCX-179 suitable for instructor-led laboratory demonstrations and group observation.
  • 3. IP Series Infinity-Corrected Optical System
  • The microscope features an IP Series infinity-corrected optical system for biological specimen observation.
  • 4. DIN Plan Achromatic Objectives
  • The KCX-179 incorporates DIN Plan Achromatic objectives designed to support a flatter image field and corrected color performance.
  • 5. Antifungal-Treated Objectives
  • The supplied configuration specifies antifungal treatment for the objective lenses.
  • 6. Quintuple Reverse-Angle Nosepiece
  • The microscope features a five-position reverse-angle revolving nosepiece.
  • 7. Ball-Bearing Nosepiece Mechanism
  • The nosepiece incorporates a ball-bearing mechanism for objective selection.
  • 8. 4X Plan Achromatic Objective
  • The 4X objective, with numerical aperture 0.10, supports low-magnification specimen scanning.
  • 9. 10X Plan Achromatic Objective
  • The 10X objective, with numerical aperture 0.25, supports general biological observation.
  • 10. 40X Spring-Loaded Objective
  • The microscope includes a 40X spring-loaded objective with numerical aperture 0.65.
  • 11. 100X Oil Immersion Objective
  • The KCX-179 incorporates a 100X spring-loaded oil immersion objective with numerical aperture 1.25.
  • 12. High-Magnification Biological Observation
  • The objective configuration supports examination of suitable prepared biological specimens across different magnifications.
  • 13. Five-Position Objective Capacity
  • The quintuple nosepiece provides five objective positions.
  • Four objective magnifications are specified in the reference configuration.
  • 14. Double-Layer Mechanical Stage
  • The microscope features a double-layer graduated rectangular mechanical stage.
  • 15. Large 185 × 142 mm Stage
  • The KCX-179 includes a mechanical stage measuring 185 × 142 mm.
  • 16. Precision Stage Cross Travel
  • The stage provides 75 × 55 mm X-Y movement for controlled specimen positioning.
  • 17. Graduated Stage Design
  • The mechanical stage incorporates graduations for specimen positioning.
  • 18. Ball-Bearing Coaxial Stage Controls
  • The microscope features coaxial stage controls supported by ball-bearing mechanisms.
  • 19. Integrated Green LED Pointer
  • The KCX-179 includes a green LED pointer for highlighting areas of interest during shared observation.
  • 20. Adjustable Pointer Brightness
  • The pointer brightness can be adjusted according to observation requirements.
  • 21. Collaborative Teaching Support
  • The pointer helps an instructor indicate specimen features during group microscopy demonstrations.
  • 22. Swing Condenser
  • The microscope incorporates a swing condenser for transmitted-light illumination.
  • 23. Condenser N.A. 0.9 / 0.25
  • The supplied condenser configuration specifies numerical aperture values of 0.9 / 0.25.
  • 24. Aspheric Condenser Lens
  • The condenser incorporates an aspheric lens.
  • 25. Adjustable Iris Diaphragm
  • The iris diaphragm allows adjustment of the illumination aperture.
  • 26. Special Daylight Blue Filter
  • The microscope includes a daylight blue optical filter for appropriate illumination adjustment.
  • 27. Köhler Illumination System
  • The KCX-179 features Köhler illumination for controlled transmitted-light observation.
  • 28. External Illumination Arrangement
  • The microscope uses an external illumination configuration.
  • 29. 12V / 50W Halogen Lamp
  • The microscope incorporates a 12V / 50W halogen light source.
  • 30. Low-Positioned Coaxial Focusing
  • The focusing system features low-positioned coaxial coarse and fine controls.
  • 31. Coarse Focusing Control
  • The coarse focusing mechanism supports initial specimen focusing.
  • 32. Fine Focusing Control
  • The fine focusing mechanism supports smaller adjustments for image clarity.
  • 33. Focusing Tension Control
  • The microscope includes a focusing tension adjustment mechanism.
  • 34. Refocusing Lock
  • The KCX-179 features a refocusing lock to support repeatable observation settings.
  • 35. Laboratory Teaching Applications
  • The microscope supports instructor-led practical microscopy education.
  • 36. Research Demonstrations
  • The multihead arrangement is suitable for collaborative scientific demonstrations.
  • 37. Group Specimen Observation
  • Several observers can participate in examination of the same specimen using the multihead configuration.
  • 38. Biological Laboratory Applications
  • The microscope supports observation of suitable prepared biological specimens.
  • 39. Professional Microscopy Training
  • The KCX-179 is suitable for training in specimen examination, optical focusing and laboratory microscopy.
  • 40. KC Scientific Works Multihead Microscope
  • The KCX-179 Multi Head Microscope is offered under the KC SCIENTIFIC WORKS teaching and research microscope range.

Working Purpose

The Multi Head Microscope KCX-179 is designed to support collaborative microscopic observation in educational institutions, research laboratories and professional training environments.

Unlike a conventional single-observer microscope, a multihead microscope allows several participants to observe the same specimen through connected viewing heads.

This arrangement is particularly useful for microscopy teaching, group demonstrations, research discussions and laboratory training.

The KCX-179 incorporates infinity-corrected DIN Plan Achromatic objectives for examination of suitable prepared specimens.

Its mechanical stage provides controlled X-Y specimen movement.

The Köhler illumination system supports transmitted-light observation.

The coaxial coarse and fine focusing controls allow the primary operator to adjust specimen focus.

An integrated green LED pointer allows an instructor or operator to highlight areas of interest during shared observation.

The microscope is intended for biological microscopy, laboratory instruction, collaborative research demonstrations and professional microscopy training.

Applications

1. Microscopy Teaching

The KCX-179 Multi Head Microscope allows instructors and students to examine the same specimen during practical training.

2. Laboratory Training

The microscope supports group-based microscopy instruction.

3. Biological Observation

The KCX-179 can be used for examination of suitable prepared biological specimens.

4. Research Laboratories

Research teams can use the microscope for collaborative optical observation.

5. Educational Institutions

The microscope is suitable for schools, colleges and universities offering advanced laboratory training.

6. Collaborative Research

Several observers can examine specimen features during research discussions.

7. Scientific Demonstrations

The microscope supports instructor-led scientific demonstrations.

8. Group Specimen Observation

The multihead arrangement allows multiple users to participate in a microscopy session.

9. Laboratory Instruction

The KCX-179 is suitable for teaching microscope operation and specimen interpretation.

10. Professional Microscopy

The microscope supports collaborative examination in professional laboratory settings.

11. Biology Departments

University biology departments can use the microscope for teaching and specimen observation.

12. Medical Education

The microscope can support educational observation of prepared biological and tissue slides.

13. Pathology Teaching

The KCX-179 can be used for group examination of prepared pathology teaching slides.

14. Microbiology Training

The microscope supports collaborative observation of appropriately prepared microorganisms.

15. Biotechnology Laboratories

The KCX-179 can be used for suitable biological specimen demonstrations.

16. Research Discussions

The microscope allows researchers to discuss observable specimen features during shared viewing.

17. Laboratory Skill Development

Students can develop practical microscopy skills through supervised demonstrations.

18. Scientific Workshops

The microscope is suitable for microscopy workshops and practical training programs.

19. Academic Research Training

The KCX-179 supports collaborative specimen observation in academic research environments.

20. Group Laboratory Demonstrations

The microscope can be used to demonstrate specimen structures to several participants simultaneously.

Advanced Multihead Observation System

The KCX-179 Multi Head Microscope is configured for shared optical observation.

A multihead microscope uses an optical distribution arrangement to direct the specimen image toward multiple observation positions.

This allows instructors, students, researchers and laboratory personnel to examine the same specimen during a coordinated microscopy session.

Multihead Observation Benefits

  • Shared specimen observation

  • Instructor-led demonstrations

  • Collaborative specimen discussions

  • Practical microscopy training

  • Group biological examination

  • Educational laboratory instruction

  • Research demonstrations

  • Visual identification of specimen features

Multihead Configuration

ParameterSpecification
Observation TypeMultihead
Optical SystemIP Series Infinity-Corrected
Number of HeadsNot Specified
Number of ObserversDepends on Final Head Configuration
Pointer TypeGreen LED
Pointer BrightnessAdjustable
Primary UseCollaborative Microscopy
Viewing ArrangementShared Specimen Image

Optical System and Objectives

The KCX-179 features infinity-corrected DIN Plan Achromatic objectives with antifungal treatment.

ObjectiveNumerical ApertureConfiguration
4X0.10DIN Plan Achromatic
10X0.25DIN Plan Achromatic
40X0.65DIN Plan Achromatic, Spring-Loaded
100X1.25DIN Plan Achromatic, Spring-Loaded, Oil Immersion

The objective system supports observation of suitable prepared specimens at different magnifications.

Magnification System

The supplied reference does not specify the eyepiece magnification.

The following table shows the calculated total magnification if 10X eyepieces are installed.

ObjectiveAssumed EyepieceCalculated Total Magnification
4X10X40X
10X10X100X
40X10X400X
100X10X1000X

Note: Final magnification specifications depend on the eyepieces supplied with the KCX-179.

Mechanical Stage

The KCX-179 Multi Head Microscope incorporates a double-layer graduated rectangular mechanical stage.

Its mechanical arrangement allows controlled positioning of compatible prepared slides.

Stage Specifications

ParameterSpecification
Stage TypeDouble-Layer Graduated Mechanical
Stage ShapeRectangular
Stage Size185 × 142 mm
X-Y Movement75 × 55 mm
Stage ControlsCoaxial
Guide MechanismBall Bearing

Köhler Illumination System

The KCX-179 features a Köhler illumination system for transmitted-light microscopy.

Köhler illumination is designed to provide controlled specimen illumination while allowing appropriate adjustment of the illumination field and aperture.

The supplied configuration incorporates an external 12V / 50W halogen light source.

Illumination Specifications

ParameterSpecification
Illumination MethodKöhler
Illumination ArrangementExternal
Light SourceHalogen
Lamp Rating12V / 50W
CondenserSwing Condenser
Iris DiaphragmIncluded
Optical FilterSpecial Daylight Blue

Condenser System

The microscope features a swing condenser with an aspheric lens.

The condenser is used to direct illumination toward the specimen and support suitable bright-field observation.

Condenser Specifications

ParameterSpecification
Condenser TypeSwing Condenser
Numerical Aperture0.9 / 0.25
Lens DesignAspheric
Iris DiaphragmIncluded
FilterSpecial Daylight Blue
Filter HolderReferenced

Focusing System

The KCX-179 incorporates a low-positioned coaxial coarse and fine focusing mechanism.

The focusing controls allow the operator to adjust the position of the optical system relative to the specimen.

Focusing Specifications

ParameterSpecification
Focusing TypeCoaxial Coarse and Fine
Control PositionLow-Positioned
Tension AdjustmentIncluded
Refocusing LockIncluded
OperationManual

Green LED Pointer System

The KCX-179 Multi Head Microscope incorporates a green LED pointer with adjustable brightness.

The pointer is intended to help an instructor or primary observer identify a particular area of interest during shared specimen observation.

Pointer Specifications

ParameterSpecification
Pointer TypeGreen LED
Brightness AdjustmentAvailable
Primary PurposeHighlighting Specimen Features
ApplicationTeaching and Collaborative Observation

Working Principle

The Multi Head Microscope KCX-179 operates using compound transmitted-light microscopy combined with a multi-observer optical distribution arrangement.

A suitable prepared specimen is placed on the mechanical stage.

The external halogen illumination system directs light through the condenser toward the specimen.

The selected objective collects transmitted light and forms a magnified intermediate image.

The infinity-corrected optical system supports image formation through its compatible optical components.

The multihead optical distribution arrangement directs the image toward the connected observation heads.

This allows multiple observers to examine the same specimen.

The green LED pointer can be used to indicate specific specimen features.

The mechanical stage provides controlled specimen positioning, while the coarse and fine focusing controls allow adjustment of image sharpness.

Basic Multihead Observation Process

  1. Microscope Setup: Position the microscope and connected viewing heads according to the supplied configuration.

  2. Specimen Preparation: Prepare or select a suitable microscope slide.

  3. Slide Positioning: Place the specimen on the mechanical stage.

  4. Illumination: Switch on the external halogen illumination system.

  5. Objective Selection: Begin observation with the lowest-power objective.

  6. Initial Focusing: Use the coarse focusing control to locate the specimen.

  7. Fine Focusing: Adjust the fine focus to obtain a clear image.

  8. Illumination Adjustment: Adjust the condenser and iris diaphragm as required.

  9. Shared Observation: Allow connected observers to examine the specimen.

  10. Pointer Adjustment: Use the green LED pointer to highlight areas of interest.

  11. Higher Magnification: Select higher-power objectives as required.

  12. Oil Immersion Observation: Use the 100X oil immersion objective with suitable immersion oil when necessary.

Typical Observation Areas

Observation AreaPurpose
Prepared Biological SlidesGroup specimen examination
Plant CellsEducational observation of cellular structures
Animal CellsCollaborative cell observation
Tissue SectionsTeaching and research demonstrations
Prepared Blood SmearsEducational microscopy
Bacterial SlidesObservation of appropriately stained specimens
MicroorganismsCollaborative microbiology demonstrations
Histology SlidesTissue structure education
Laboratory Teaching SlidesInstructor-led observation
Research SpecimensShared optical examination

Educational and Research Benefits

The KCX-179 Multi Head Microscope supports collaborative learning and scientific observation.

It can help users develop skills in:

  • Shared microscopic observation

  • Specimen identification

  • Compound optical microscopy

  • Objective selection

  • Mechanical stage operation

  • Coarse and fine focusing

  • Köhler illumination adjustment

  • Oil immersion microscopy

  • Biological specimen examination

  • Group scientific discussion

  • Laboratory instruction

  • Research demonstrations

Microscope Compatibility and Usage

The KCX-179 Multi Head Microscope is intended for collaborative examination of suitable prepared biological specimens.

It can be used in educational institutions, biological laboratories, research departments and microscopy training centers.

The microscope should be positioned on a stable laboratory bench with sufficient space for the connected observation heads.

The external halogen illumination system should be operated according to its supplied electrical specifications.

Prepared slides should be positioned on the mechanical stage.

Observation should begin with the lower-power objective.

The coarse and fine focusing controls should be adjusted carefully.

The green LED pointer can be used to highlight areas of interest during shared viewing.

The 100X oil immersion objective should be used with suitable immersion oil.

After use, the optical components should be cleaned using appropriate optical cleaning materials.

The microscope should be stored in a clean and dry environment.

Suggested Products

View all products →
▧ Company Profile