The Surgical Ophthalmic Microscope KCX-210 is intended to provide magnified binocular observation of small structures and working areas.
The ergonomic binocular viewing head supports adjustment of the observer's viewing position.
The wide-field eyepieces provide direct optical observation.
The magnification changer allows the operator to select among the available optical settings.
The 250 mm objective lens establishes the reference working-distance configuration.
The manual fine-focusing mechanism supports adjustment of image sharpness.
The articulated support arm allows the microscope head to be positioned over the observation area.
The mobile floor stand provides a wheeled support arrangement.
The monitor and foot-control pedals shown in the supplied image suggest additional viewing and control capabilities, but their specific functions are not established by the supplied technical specifications.
For ophthalmic clinical procedures, suitability must be verified through appropriate technical documentation, ophthalmic illumination specifications, risk assessment and medical-device compliance.
Applications
1. Ophthalmic Microscope Training
The KCX-210 may support supervised education in operating microscope handling.
2. Ophthalmic Anatomy Demonstrations
The microscope may be used for observation of suitable eye anatomy models.
3. Microsurgical Skills Training
The proposed configuration may be evaluated for magnified observation during non-clinical skills training.
4. Medical College Demonstrations
The microscope may support educational demonstrations of operating microscope components.
5. Surgical Instrument Familiarization
The KCX-210 may be used to demonstrate microscope positioning and optical controls.
6. Binocular Microscope Education
The system supports instruction in binocular viewing arrangements.
7. Magnification Changer Demonstrations
The microscope can be used to demonstrate selectable optical magnification settings.
8. Fine-Focusing Training
The KCX-210 supports instruction in manual fine-focus adjustment.
9. Ergonomic Viewing Demonstrations
The adjustable observation head supports teaching about viewing posture.
10. Medical Equipment Training
The microscope may support familiarization with floor-standing optical equipment.
11. Ophthalmic Research Training
The proposed configuration may be evaluated for suitable non-clinical research activities.
12. Laboratory Optical Inspection
The microscope may support appropriate magnified observation of laboratory specimens.
13. Precision Component Inspection
The optical system may be used for inspection of suitable small components.
14. Surgical Equipment Demonstrations
The KCX-210 may be used to demonstrate operating microscope setup.
15. Medical Technology Education
The microscope may support educational instruction in optical medical equipment.
16. Clinical Simulation Laboratories
The proposed configuration may be evaluated for simulation-based training.
17. Microscope Positioning Exercises
The articulated arm supports demonstrations of microscope head positioning.
18. Working-Distance Demonstrations
The microscope can be used to illustrate the relationship between objective focal length and working distance.
19. Optical Observation Documentation
Digital observation may be possible if a compatible camera and functioning display system are confirmed.
20. Ophthalmic Equipment Familiarization
The KCX-210 may support basic training in the operation and adjustment of surgical-style microscopes.
Typical Observation and Training Uses
| Observation Subject | Purpose |
|---|
| Eye Anatomy Models | Ophthalmic educational demonstration |
| Artificial Eye Models | Microscope positioning training |
| Microsurgical Training Models | Non-clinical skills practice |
| Precision Instruments | Magnified component observation |
| Optical Test Targets | Basic magnification evaluation |
| Fine Mechanical Components | Surface inspection |
| Educational Specimens | Optical observation |
| Surgical Simulation Materials | Training and demonstration |
Working Principle
The Surgical Ophthalmic Microscope KCX-210 uses an optical magnification system to provide an enlarged view of the observation area.
The objective lens collects light from the specimen or working field.
The optical system forms an image that is observed through the binocular eyepieces.
The magnification changer modifies the optical magnification according to the selected setting.
The interpupillary adjustment allows the viewing tubes to be positioned for the observer.
The diopter adjustment compensates for differences in ocular focus, subject to the confirmed adjustment specification.
The manual fine-focusing system allows image sharpness to be adjusted.
The articulated arm supports positioning of the microscope head over the required observation area.
The reference image also shows a monitor and foot pedals, but the imaging path and pedal functions are not specified.
An appropriate ophthalmic illumination system is essential for clinical application; no such system has been technically documented in the supplied reference.
Basic Observation Procedure
The following is a non-clinical setup and demonstration procedure, not a surgical operating protocol.
Position the Stand: Place the microscope on a stable, level surface.
Secure the Base: Engage the wheel locks if fitted.
Inspect the Equipment: Check the visible stand, arm and optical head for damage.
Check the Configuration: Confirm the installed eyepieces, objective and magnification changer.
Prepare a Training Model: Position a suitable non-clinical observation target.
Adjust the Support Arm: Move the microscope head over the target.
Set the Viewing Head: Adjust the ergonomic binocular head.
Adjust Interpupillary Distance: Set the eyepiece spacing for comfortable binocular viewing.
Select Magnification: Begin with an appropriate low magnification.
Provide Suitable Lighting: Use a verified, appropriate illumination arrangement.
Focus the Image: Adjust the manual fine-focusing control.
Observe the Target: Examine the visible features.
Change Magnification: Select another supported setting if required.
Readjust Focus: Refine the image after magnification changes.
Document Observations: Record the results of the demonstration.
Return to Storage Position: Secure the articulated arm and equipment after use.
Magnification System
The supplied reference contains two alternative magnification-changer configurations.
Option A: Three-Step Magnification Changer
| Setting | Listed Magnification |
|---|
| Step 1 | 5X |
| Step 2 | 10X |
| Step 3 | 20X |
The reference does not establish whether these values represent final system magnification or magnification-changer values.
Option B: Five-Step Magnification Changer
| Setting | Changer Factor |
|---|
| Step 1 | 0.4X |
| Step 2 | 0.6X |
| Step 3 | 1.0X |
| Step 4 | 1.6X |
| Step 5 | 2.5X |
These values are listed as changer factors, not verified final system magnifications.
Final magnification depends on the optical system, including the eyepiece, objective and any intermediate optical factors.
The supplied reference does not provide enough information to calculate the final magnification range of the five-step configuration reliably.
Binocular Viewing System
| Parameter | Specification |
|---|
| Viewing System | Binocular |
| Head Type | Ergonomic |
| Angular Adjustment | 0°–180° |
| Standard Eyepieces | 12.5X WF / 16 mm |
| Optional Eyepieces | 15X WF / 16 mm |
| Interpupillary Distance | 55–75 mm |
| Diopter Adjustment | Reference States ±6 mm |
| Camera Port | Not Specified |
The diopter adjustment is reproduced from the reference, but diopter adjustment is conventionally specified in diopters rather than millimetres. The unit requires verification.
Objective Lens and Working Distance
| Parameter | Specification |
|---|
| Objective Lens | F-250 mm |
| Nominal Working Distance | 250 mm |
| Objective Type | Not Specified |
| Objective Numerical Aperture | Not Specified |
| Optical Resolution | Not Specified |
| Field of View at Specimen | Not Specified |
Manual Fine-Focusing System
| Parameter | Specification |
|---|
| Focusing Type | Manual |
| Fine Focusing | Specified |
| Motorized Focus | Not Confirmed |
| Focusing Travel | Not Specified |
| Focus Resolution | Not Specified |
Mobile Stand and Articulated Arm
The supplied image shows a mobile floor stand supporting the microscope head.
| Parameter | Reference Information |
|---|
| Stand Arrangement | Floor Standing |
| Mobility | Wheeled Base Visible |
| Vertical Support | Column Visible |
| Microscope Support | Articulated Arm Visible |
| Body Colour | White |
| Material | Metal (Reference) |
| Arm Reach | Not Specified |
| Stand Height | Not Specified |
| Base Dimensions | Not Specified |
| Load Capacity | Not Specified |
| Wheel Locking Mechanism | Not Confirmed |
Monitor and Imaging Arrangement
A monitor is visible in the supplied image.
| Parameter | Specification |
|---|
| Monitor | Visible in Reference Image |
| Monitor Size | Not Specified |
| Display Resolution | Not Specified |
| Camera Type | Not Specified |
| Camera Resolution | Not Specified |
| Video Interface | Not Specified |
| Recording Function | Not Confirmed |
| Live Display Function | Not Confirmed |
The presence of a monitor does not independently establish the supplied camera, recording or display capabilities.
Foot-Control System
The reference identifies a foot-control pedal, and two pedals are visible in the image.
| Parameter | Specification |
|---|
| Foot Control | Referenced |
| Pedals | Visible in Image |
| Controlled Functions | Not Specified |
| Motorized Focus | Not Confirmed |
| Motorized Zoom | Not Confirmed |
| Electrical Control Interface | Not Specified |
Ophthalmic Illumination and Clinical Verification
The supplied reference does not specify an ophthalmic illumination system.
Before KCX-210 is described as suitable for clinical ophthalmic surgery, the following should be documented:
Illumination source and intensity
Coaxial or other ophthalmic illumination configuration
Red-reflex capability, if required for intended procedures
Retinal light-exposure safety characteristics
Illumination adjustment and filtering
Optical resolution and field of view
Stand stability and mechanical safety
Electrical safety and electromagnetic compatibility
Medical-device regulatory status
Intended clinical procedures and validated operating conditions
These capabilities are not confirmed features of the supplied KCX-210 reference.
Educational and Laboratory Benefits
The proposed KCX-210 Surgical Ophthalmic Microscope configuration may support:
Binocular optical observation
Microscope handling education
Ophthalmic anatomy demonstrations
Non-clinical microsurgical training
Magnification changer demonstrations
Fine-focusing practice
Ergonomic viewing instruction
Working-distance demonstrations
Articulated-arm positioning exercises
Medical equipment familiarization
Clinical simulation laboratory activities
Optical instrument inspection
Precision component observation
Laboratory equipment demonstrations
Ophthalmic education programs
Product Configuration and Compatibility
The KCX-210 reference identifies binocular viewing, a 250 mm objective, alternative magnification changers and manual fine focusing.
The supplied image additionally shows a floor stand, articulated arm, monitor and foot pedals.
Camera compatibility, imaging functionality, ophthalmic illumination, motorized operation and medical-device certification remain unverified.
For procurement, a final model-specific technical datasheet should identify the exact supplied optical configuration and accessories.