☎ +91 99926 66137✉ info@kcscientificworks.com
Scientific Instruments for Better TomorrowQuality DocumentsCompany ProfileDealer / Enquiry
Scientific Instruments for Better TomorrowEnquire Now
← Back to Analyzers
BIO CHEMISTRY ANALYZER KCX-349
Analyzers / Biochemistry Analyzers

BIO CHEMISTRY ANALYZER KCX-349

The Bio Chemistry Analyzer KCX-349 by KC SCIENTIFIC WORKS is a photometric laboratory analyzer featuring a 7-inch touchscreen, automatic wavelength selection, Peltier temperature regulation, and an integrated thermal printer. Supporting up to 300 test parameters and 200,000 stored results, it offers multiple analytical methods and quality-control functions for biochemical testing.

SKU: KCX-349

Category: Analyzers, Biochemistry Analyzers

Description


Technical Specifications

ParameterSpecification
Product NameBio Chemistry Analyzer
Model NumberKCX-349
BrandKC SCIENTIFIC WORKS
Analysis PrinciplePhotometric Analysis
Test MethodsEndpoint, Fixed-Time Kinetics, Multipoint Kinetics, Dual-Wavelength Absorbance and Coagulation Modes
Standard/Factor MethodSupported
Calibration StandardsUp to 8 Standards
Optical SystemInterference Filter-Based Photometric System
Absorbance Range0.0000–3.0000
Linearity±1%
Repeatability0.001 (as specified)
Wavelength SelectionAutomatic via Filter Wheel
Wavelengths240, 405, 450, 505, 546, 578 and 630 nm
Additional Filter Positions2 Free Positions
Light Source6V/10W Tungsten Halogen Lamp
DetectorPhotodiode
Thermal SystemPeltier-Regulated
Temperature Settings25°C, 30°C, 37°C and Room Temperature
Temperature Accuracy±0.3°C
Flow CellQuartz
Flow Cell Volume32 µL
Optical Path Length10 mm
Removable CuvetteSquare and Round
Display7.0-Inch Color Touchscreen
External InputKeyboard and Mouse Support
PrinterInbuilt 57 mm Thermal Printer
Suction PumpPressure Auto-Releasing Peristaltic Pump
Suction Volume300 µL to 3.0 mL
Carryover ReductionAir Column Facility After Each Sample
Test Parameter CapacityUp to 300
Result StorageUp to 200,000 Test Results
Patient InformationEditable
QC Data StorageSupported
Standard Result StorageSupported
Quality ControlLevey–Jennings Charts with Westgard Rules
QC GraphsAutomatic Drawing
ProcessorARM Cortex-A8, 720 MHz
DDR2 SDRAM1 Gbit
Flash Memory256 MB
Operating Temperature10°C–37°C
Relative HumidityBelow 85%
Power Input10–240 V AC (as supplied; verification required)
Frequency50/60 Hz
External Power Adapter19V, 4.7A
Dimensions400 × 300 × 160 mm (L × B × H)
Weight6 kg

Supported Test Methods

The KCX-349 Bio Chemistry Analyzer supports multiple analytical methods for laboratory biochemical measurements.

Test MethodDescription
Endpoint MethodMeasurement at the defined reaction endpoint
Standard MethodMeasurement using a reference standard
Factor MethodConcentration calculation using a defined factor
Two-Point KineticsFixed-time measurement at two points
Multipoint KineticsMeasurement using multiple readings
Multistandard MethodCalibration using up to eight standards
Biochromatic / Dual-WavelengthAbsorbance measurement using two wavelengths
Absorbance MethodDirect photometric absorbance measurement
Coagulation ModeSupported as listed in the supplied specifications

The suitability of each analytical mode depends on the assay reagents, calibration requirements, and validated instrument configuration.

Optical System Specifications

The KCX-349 uses a photometric optical system with interference filters and automatic wavelength selection.

Optical ParameterSpecification
Optical PrinciplePhotometric Analysis
Filter SelectionAutomatic Filter Wheel
Absorbance Range0.0000–3.0000
Linearity±1%
Repeatability0.001
Light Source6V/10W Tungsten Halogen Lamp
DetectorPhotodiode
Standard Wavelengths240, 405, 450, 505, 546, 578, 630 nm
Additional Positions2
Flow Cell32 µL Quartz
Optical Path Length10 mm

The supplied reference contains unclear wording for optical resolution and wavelength precision. These values should be confirmed against the original technical documentation before publication.

Salient Features

1. Photometric Analytical System

The KCX-349 incorporates a photometric system designed for measuring absorbance in supported biochemical assays.

2. Multiple Test Methods

The analyzer supports endpoint, standard/factor, fixed-time kinetics, multipoint kinetics, multistandard, and dual-wavelength measurement methods.

3. Automatic Wavelength Selection

The filter wheel automatically selects the appropriate installed optical filter according to the selected test configuration.

4. Wide Absorbance Measurement Range

The analyzer offers a specified absorbance range of 0.0000 to 3.0000.

5. Seven-Inch Color Touchscreen

The 7-inch touchscreen provides an interface for instrument operation, test configuration, result review, and quality-control functions.

6. Long-Life Tungsten Halogen Lamp

A 6V/10W tungsten halogen lamp serves as the optical light source.

7. Photodiode Detector

The photodiode detector receives transmitted light and supports photometric measurement.

8. Peltier-Regulated Temperature System

The instrument supports temperature settings of 25°C, 30°C, 37°C, and room temperature.

9. Temperature Accuracy of ±0.3°C

The specified thermal accuracy is ±0.3°C under applicable operating conditions.

10. Quartz Flow Cell

The analyzer includes a quartz flow cell with a specified volume of 32 µL and a 10 mm optical path length.

11. Removable Cuvette Compatibility

The supplied specifications list removable square and round cuvettes.

12. Integrated Thermal Printer

A built-in 57 mm thermal printer supports direct printing of analytical results.

13. External Keyboard and Mouse Support

The analyzer supports an external keyboard and mouse for convenient data entry and navigation.

14. Peristaltic Suction Pump

A pressure auto-releasing peristaltic pump is provided for sample aspiration.

15. Adjustable Suction Volume

The specified suction volume ranges from 300 µL to 3.0 mL.

16. Air Column Facility

An air column facility after each sample is provided to help reduce sample carryover.

17. Up to 300 Test Parameters

The instrument can store configurations for up to 300 test parameters.

18. Large Result Storage

The KCX-349 supports storage of up to 200,000 test results with editable patient information.

19. Quality-Control Monitoring

The analyzer supports Levey–Jennings charts, Westgard rules, and automatic QC graph generation.

20. Compact Benchtop Design

With dimensions of 400 × 300 × 160 mm and a specified weight of 6 kg, the analyzer is designed for laboratory bench installation.


Key Features

  • Advanced Photometric Analysis: Designed for accurate absorbance measurement in compatible biochemical laboratory assays.
  • 7-Inch Color Touchscreen: Large touchscreen display for convenient operation, test selection, and result monitoring.
  • Multiple Testing Methods: Supports Endpoint, Fixed-Time Kinetics, Multipoint Kinetics, Multistandard, and Dual-Wavelength Analysis.
  • Automatic Wavelength Selection: Built-in filter wheel with seven specified wavelengths and two additional filter positions.
  • Wide Absorbance Range: Measurement range from 0.0000 to 3.0000 with specified ±1% linearity.
  • Peltier Temperature Control: Supports 25°C, 30°C, 37°C, and room-temperature settings with ±0.3°C accuracy.
  • High-Quality Optical System: Equipped with a 6V/10W tungsten halogen lamp and photodiode detector.
  • Quartz Flow Cell: Features a 32 µL quartz flow cell with a 10 mm optical path length.
  • Automatic Sample Suction: Pressure auto-releasing peristaltic pump with adjustable suction volume from 300 µL to 3.0 mL.
  • Reduced Sample Carryover: Air column facility after each sample helps minimize carryover.
  • 300 Test Parameters: Supports storage and configuration of up to 300 biochemical test parameters.
  • Large Memory Capacity: Stores up to 200,000 test results with editable patient information.
  • Advanced Quality Control: Includes Levey–Jennings charts, Westgard rules, and automatic QC graph generation.
  • Inbuilt Thermal Printer: Integrated 57 mm thermal printer for convenient test-result printing.
  • External Keyboard and Mouse Support: Allows convenient data entry and instrument navigation.
  • High-Performance Processor: ARM Cortex-A8 processor operating at 720 MHz with 1 Gbit DDR2 SDRAM and 256 MB flash memory.
  • Compact Laboratory Design: Dimensions of 400 × 300 × 160 mm and weight of approximately 6 kg.
  • Flexible Power Operation: Supplied with a 19V, 4.7A external power adapter.

Working Purpose

The KCX-349 operates on the principle of photometric absorbance measurement.

A tungsten halogen lamp produces light that passes through the selected optical filter.

The filtered light travels through the sample contained in the flow cell or compatible cuvette.

The photodiode detector measures the light transmitted through the sample.

The instrument determines absorbance from the relationship between incident and transmitted light.

Depending on the selected analytical method, absorbance readings are used with calibration information to calculate the reported result.

General Analytical Workflow

  1. Test Selection: The operator selects a configured biochemical test.

  2. Temperature Setting: The appropriate reaction temperature is selected.

  3. Sample Preparation: The specimen and assay reagents are prepared according to the validated test procedure.

  4. Sample Aspiration: The peristaltic suction system draws the prepared reaction mixture when the flow-cell mode is used.

  5. Wavelength Selection: The filter wheel selects the configured wavelength.

  6. Photometric Measurement: Light passes through the sample and reaches the detector.

  7. Signal Processing: The instrument processes the absorbance measurement.

  8. Result Calculation: The result is calculated using the selected method and calibration information.

  9. Quality Review: The operator reviews applicable quality-control information.

  10. Result Storage: The result is stored with the associated patient or sample information.

  11. Report Printing: The result can be printed using the integrated thermal printer.

Quality Control System

The KCX-349 incorporates quality-control features for monitoring analytical performance.

Levey–Jennings Charts

Levey–Jennings charts allow laboratory personnel to review quality-control results over time.

Westgard Rules

Westgard rules provide a framework for evaluating quality-control data against defined acceptance criteria.

Automatic QC Graphs

The analyzer supports automatic generation of quality-control figures.

QC and Standard Data Storage

Quality-control and standard results can be stored for later review.

These functions support laboratory quality management when used with suitable control materials, validated procedures, and established acceptance limits.

Applications

1. Clinical Biochemistry Laboratories

The KCX-349 supports photometric biochemical testing in suitable clinical laboratory workflows.

2. Diagnostic Laboratories

The analyzer can be used for compatible biochemical investigations in diagnostic testing facilities.

3. Hospital Laboratories

It supports routine biochemical measurement and result-management workflows in hospital laboratory environments.

4. Pathology Laboratories

The analyzer provides photometric measurement capabilities for suitable biochemical assays.

5. Medical Colleges

The KCX-349 can support instruction and demonstrations involving biochemical analysis and laboratory instrumentation.

6. Biotechnology Laboratories

The instrument can be used for suitable photometric measurements in biotechnology research.

7. Pharmaceutical Research Laboratories

The analyzer supports compatible analytical procedures involving absorbance measurements.

8. Research Institutions

It can assist with photometric laboratory investigations requiring endpoint or kinetic measurements.

9. Educational Laboratories

The KCX-349 supports practical training in photometry, absorbance, calibration, and analytical quality control.

10. Laboratory Training Centers

The analyzer can be used to demonstrate instrument operation, quality-control procedures, and biochemical test methods.

11. Healthcare Diagnostic Centers

It offers result storage, printing, and analytical functions for compatible diagnostic laboratory workflows.

12. Biomedical Research Laboratories

The KCX-349 can support biochemical research involving validated photometric methods.

Standard Accessories

The KCX-349 is supplied with the following listed standard accessories.

AccessoryDescription
Printer Paper RollFor the Integrated Thermal Printer
Removable CuvetteFor Compatible Measurement Procedures
Optical MouseExternal Input Accessory
External KeyboardFor Data Entry and Operation
AC AdapterExternal Power Adapter

The exact accessory quantities and supplied cuvette configuration should be confirmed in the purchase documentation.

Benefits of the KCX-349

Multiple analytical methods: Supports endpoint, kinetic, standard-based, and dual-wavelength measurement techniques.

Automatic wavelength selection: The filter wheel provides automated selection of installed optical filters.

Temperature regulation: The Peltier system offers defined operating temperature settings.

Touchscreen operation: The 7-inch color display supports convenient instrument interaction.

Result management: Storage of up to 200,000 results supports laboratory documentation.

Quality-control functions: Levey–Jennings charts and Westgard rules support analytical quality monitoring.

Integrated printing: The thermal printer allows results to be printed directly.

Compact construction: The benchtop design is suitable for laboratories with limited workspace.

Suggested Products

View all products →
▧ Company Profile